Always make sure all high-pressure water has been removed from the valve by following the machine manufacturers' safety instructions. Failure to do so can cause severe injury or death.
-
Turn OFF all hydraulic and water pressure to the bleed-down valve.
-
Loosen the hydraulic hose from the hydraulic fitting using 7/8" and 3/4" wrench.
-
-
-
Unthread the hydraulic hose from the hydraulic fitting.
-
Loosen the 1/4" gland nut from the side inlet of the valve body.
-
Unthread the 1/4" gland nut from the side inlet of the valve body.
-
-
-
Clean the 3/8" gland nut of all Blue Goop with isopropyl alcohol.
-
Loosen the 3/8" high-pressure gland from the outlet adapter using 13/16" and 1" wrench.
-
Unthread the 3/8" high-pressure gland from the outlet adapter.
-
-
-
Clean the 3/8" gland nut of all Blue Goop with isopropyl alcohol.
-
Loosen the hydraulic fitting from the adapter fitting using 1-1/4" and 7/8" wrench.
-
Unthread the hydraulic fitting from the adapter fitting.
-
-
-
Apply an O-ring lubricant to the O-ring from the kit for the hydraulic fitting.
-
Replace the O-ring on the hydraulic fitting with the O-ring from the kit (smallest O-ring in kit).
-
Loosen the adapter fitting from the actuator housing using 1-1/4" and 1-1/16" wrench.
-
-
-
Unthread the adapter fitting from the actuator housing.
-
Apply an O-ring lubricant to the largest O-ring from the kit.
-
Replace the O-ring on the adapter fitting with the largest O-ring from the kit.
-
-
-
Loosen the actuator housing from the valve body using 1-1/16" and 7/8" wrench.
-
Unthread the actuator housing from the valve body.
-
Push the piston out of the actuator housing through the oil port using the included dowel.
-
-
-
Discard the O-ring and back-up ring from the piston.
-
Inspect the piston, if damage is visible, replace.
-
Apply an O-ring lubricant to the O-ring and back-up ring.
-
-
-
Slide the new back-up ring (flat) into the groove of the piston.
-
Make sure the concave side of the back-up ring is towards the O-ring.
-
Slide the new O-ring (rounded) into the groove of the piston.
-
Insert the piston assembly into the actuator housing and push with the included dowel.
-
-
-
Loosen the outlet fitting from the bleed down valve body using 7/8" and 13/16" wrench.
-
Unthread the outlet fitting from the bleed down valve body.
-
Remove the high-pressure seat from the bleed down valve body and discard.
-
-
-
Remove theflow reducer from the outlet adapter.
-
Clean the outlet adapter and the flow reducer of all Blue Goop with isopropyl alcohol.
-
Loosen the back-up screw from the top of the bleed down valve body using a 5/16" socket wrench.
-
-
-
Unthread the seal back-up screw from the top of the bleed down valve body.
-
Clean the seal back-up screw with isopropyl alcohol.
-
Push the components through the bleed down valve body with the included dowel.
-
-
-
Clean the bleed down valve body with isopropyl alcohol or a similar cleaning agent.
-
Apply ahigh vacuum grease to the needle.
-
Slide the back-up screw on to the needle so the flat end of the needle is flush with the non threaded part of the back-up screw.
-
-
-
Slide the bushing onto the point of the needle with the chamfered end towards the back-up screw.
-
Place the hoop onto the high-pressure seal with the tapered end towards the high-pressure seal and opposite from the O-ring.
-
Place the high-pressure seal assembly onto the point of the needle with the hoop, first.
-
-
-
Apply a high vacuum grease to the exterior of the high-pressure seal, hoop, and bushing.
-
Apply a high vacuum grease to the internal threads of the bleed down valve body.
-
Insert the high pressure needle assembly into the top of the bleed down valve body with the point first.
-
-
-
Push the seal back-up screw inside of the valve body until it bottoms out.
-
Take the seal back-up screw out of the body and apply a layer of Blue Goop to the threads.
-
Thread in the back-up screw into the top of the bleed down valve body.
-
-
-
Tighten the back-up screw to the top of the bleed down valve body using a 5/16" socket wrench.
-
Place the flow reducer into the hole beneath the seat cavity in the outlet adapter.
-
Apply a layer of Blue Goop to the external threads and the seat cavity of the outlet adapter.
-
-
-
Place poppet seat into seat cavity of outlet adapter
-
Apply a layer of blue goop to top of poppet seat sitting in outlet adapter
-
Thread outlet adapter into valve body
-
-
-
Using a 1" wrench on outlet adapter and a 7/8" wrench on the valve body, tighten securely
-
Apply a layer of blue goop to external threads of valve body
-
Thread actuator housing onto valve body
-
-
-
Tighten using a 1-1/16" wrench on actuator housing and a 7/8" wrench on valve body
-
Apply blue goop to 3/8" gland nut threads
-
Thread 3/8" gland nut with HP tubing into bleed down valve adapter
-
-
-
Tighten gland nut into bleed down valve adapter using 13/16" and 5/8" wrench
-
Apply blue goop to 1/4" gland nut threads
-
Thread 1/4" gland nut into side of bleed down valve body
-
-
-
Tighten gland nut to side of bleed down valve body with using 3/4" and 5/8" wrench
-
Thread adapter fitting into actuator housing
-
Tighten adapter fitting into actuator housing using 1-1/4" and 1-1/16" wrench
-
-
-
Thread hydraulic fitting into hydraulic adapter
-
Tighten hydraulic fitting into hydraulic adapter
-
Thread hydraulic hose onto hydraulic fitting
-
-
-
Tighten hydraulic hose to hydraulic fitting using 7/8" and 3/4" wrench
-
Turn pump ON and continue cutting process
-