Step Lines
- | [* black] Clean 3/8" gland nut of all |
---|---|
- | [* black] Loosen 3/8" |
- | [* black] Unthread 3/8" |
+ | [* black] Clean the 3/8" gland nut of all Blue Goop with isopropyl alcohol. |
+ | [* black] Loosen the 3/8" high-pressure gland from the outlet adapter using 13/16" and 1" wrench. |
+ | [* black] Unthread the 3/8" high-pressure gland from the outlet adapter. |